英文字典中文字典Word104.com



中文字典辭典   英文字典 a   b   c   d   e   f   g   h   i   j   k   l   m   n   o   p   q   r   s   t   u   v   w   x   y   z   







請輸入英文單字,中文詞皆可:

請選擇你想看的字典辭典:
單詞字典翻譯
Viggo查看 Viggo 在Google字典中的解釋Google英翻中〔查看〕
Viggo查看 Viggo 在Yahoo字典中的解釋Yahoo英翻中〔查看〕





安裝中文字典英文字典查詢工具!


中文字典英文字典工具:
選擇顏色:
輸入中英文單字

































































英文字典中文字典相關資料:
  • What is the K-factor rating? - Hammond Power Solutions
    Transformers with a rated K-factor of 4, 9, 13, 20 are available For balanced loading, a transformer with a K-factor of 4 should be specified when no more than 50% of the total load is non-linear A transformer with K-factor 9 should be specified when 100% of the load is non-linear
  • Guide to transformer harmonics and k-factor - Maddox
    A transformer built for usual service conditions has a K-1 rating (a K-factor of 1 means there is no harmonic distortion in the system) K-factor ratings go all the way up to 50, but it’s rare to see anything above K-20 in the commercial and industrial market
  • What is a transformer K-factor rating? - ABB
    K-factor of 4 or 13 is typical and is frequently specified and installed When transformers use a K-factor value, they are said to be K-rated and this fact is stated 50 on the transformer nameplate as shown in figure 3 circled in red UL has designated the K-factor as a means of rating a transformer’s ability to handle loads that generate
  • K-Factor rated transformer for deal with harmonic generating loads
    Typically a K-13 rated transformer is sufficient for most applications Loads approaching 100% non-linear or more than 75% THD should incorporate a K-20 rated transformer Over the past several years there has been dramatic growth in the use of equipment incorporating switching type power supplies
  • How to Determine the K- Rating of the Transformer?
    The correct manner of determining the required k-rating of a transformer can be demonstrated by the following example: Example: If the measured (or computer-forecast) current is as follows, what K-rating of transformer would be required to carry this load? True rms amperes = 73 3 amperes; h1 = 52 45 amperes ; h3 = 42 27 amperes ; h5
  • K-factor Transformers - Power Quality Blog
    A transformer “K-factor” rating conveys its ability to manage varying degrees of nonlinear loads without exceeding the rated temperature rise limits For any given nonlinear load, if the harmonic current components are known, the K-factor can be calculated and compared to the transformer’s nameplate K-factor
  • K Factor of Transformer: Significance, Rating Formula - Electrical Ampere
    The K factor of a transformer is a critical measure that helps in assessing and addressing these challenges This article explores the concept of the K factor in transformers, how it affects transformer ratings, and the mathematical formula used to calculate it
  • What is K-factor rated transformer? - Electrical Classroom
    K-factor rated transformers are capable of withstanding the heating effects caused by harmonic load currents They are specially designed for non-linear harmonics generating loads It is defined in the ANSI IEEE C57 110 standard
  • K-rated or harmonic mitigating transformers - Consulting - Specifying . . .
    In practical terms, the most common k-rated transformers typically have a k rating of 4, 7, 13, or 20, which corresponds to harmonic producing equipment totaling up to 35%, 50%, 75%, and 100% of downstream load, respectively
  • What is the difference between K-13 (Type NLP) and K-4 (Type NL) rated . . .
    Square D Schneider Electric recommends K-4 rated Transformers for computer and other similar loads found in commercial and industrial systems for duty cycles (24 hour average loading) of 80-95% If the duty cycle is expected to exceed 95%, then K-13 would be needed





中文字典-英文字典  2005-2009

|中文姓名英譯,姓名翻譯 |简体中文英文字典