SBOR Series - Outdoor Pole High Mount - Acuity Brands Ships same day if entered before noon or next day if entered after noon! The SBOR Series outdoor rated sensor incorporates passive infrared (PIR) technology into a line powered motion sensor Designed to mount directly through a 1 2 inch knockout (7 8 inch diameter hole)
What is the CMR (6,9,10) sensors default occupancy Time . . . - Salesforce I've provided the CMR programming instructions link to verify defaults setting for the occupancy time delay and Minimum On Time Delay which are highlighted yellow below NOTE: For further assistance, please contact SensorSwitch Technical Support via:
OPERATIONAL SETTINGS - Acuity Brands FAN ASHRT provides a minimum fan run-time setting so that air circulation and energy code requirements (as in ASHRAE 62 2) can be met Both versions utilize two isolated power relays, and are set to automatically turn both the lighting and fan load on when initial occupancy is detected Sensor settings can be
Low Voltage Interval Timer Swtich - SENSORWORX The SENSORWORX interval timer switch provides an automatic lighting control solution that is intuitive to operate Designed with contractors in mind, the unit is significantly shallower than typical timers, resulting in less crowded wall boxes
WSD 2P - rexel-cdn. com Patent pending LampMaximzer technology is also present in this sensor, providing an additional minimum on time (disabled by default) to be used if desired This state-of-the-art design requires no field calibration or sensitivity adjustments P2-Manual 2SA = Both Poles Manual
WALL SWITCH SENSOR Enables the unit to operate as a toggle switch by disabling the PIR sensor (recommended for testing purposes only) 2 OCCUPANCY TIME DELAY The length of time an occupancy sensor will keep the lights on after it last detects occupancy (assuming Minimum On Time, if engaged, has been met) 3 ON MODE AUTOMATIC ON
1. 0Section Includes - SensorSwitch Wall Switch sensors shall have field programmable adjustments for selecting operational modes, occupancy time delays, minimum on time, and photocell set-point as applicable All models shall be capable of both Auto-On and Manual On operation
Relay on and off duration control - PENN Controls - LIT-12011459 . . . Minimum on time: (ONT) Maintains the relay in the On state for the selected minimum time after reaching the On condition and overrides any sensor input that would normally switch the relay off during the Minimum On Time interval
CM Series - Ceiling mount, low voltage sensors - Acuity Brands The CM is a low voltage sensor that easily mounts directly to a ceiling tile or a metallic grid Ceiling mount sensors are offered in a multitude of configurations which address many applications