  • Programming 4204 4229 Relay - SafeHomeCentral
    12 1st 4204 13 2nd4204 14 3rd4204 15 4th 4204 Make sure module’s DIP switches are set to the selected address 9 Screen displays “01 Rly Position” “1-4” (note: this should only have a choice of 1-2, do not try to set up a relay 3 or 4, address 07-11 is for a 4229, and this unit only has 2 relays) Press 1* 10 Screen displays:
  • ADEMCO 4204 - Relay Module Installation Instructions - ManualsLib
    Summary of Contents for ADEMCO 4204 - Ademco Relay Module Page 1: Installation Instructions N8909 9 97 ¨ No 4204 RELAY MODULE For Use With Control Communicators Supporting Relay Module Connection Via Keypad Lines INSTALLATION INSTRUCTIONS ENERAL INFORMATION When the 4204 is mounted remotely , holes on its back permit it to be mounted
  • Relay Module Connection Via Keypad Lines INSTALLATION INSTRUCTIONS
    The 4204 Relay Module adds from one to four dry, form C (SPDT) relay outputs to compatible control communicators It interfaces to the controlÕs keypad wiring The 4204 can be mounted inside the controlÕs cabinet or mounted remotely If mounted remotely, the 4204 has two forms of protection First, the 4204 has a built-in tamper switch which
  • Honeywell 4204 - Ademco Relay Module Manual - ManualOwl. com
    Get immediate support for your Honeywell 4204 questions from HelpOwl com Recent Honeywell 4204-related questions: I'm Having A Problem With A 4204 Relay Installed an led to show when the system is armed or disarmed An expander is connected to the fa 16 How To Program A Ademco 4204 How To Cahnge Owner's Security Code On A Ademco4204 Key Pad -
  • ADEMCO 4204 Relay Module – Installation Instructions
    inside of the 4204’s cover (if the cover is used) or to the inside of the control’s cover CONNECTIONS AND SETTINGS Select and set an address for the 4204, using its DIP switch as shown in the DIP switch table Each 4204 must be assigned a unique address so the control can identify and communicate with the 4204
  • ADEMCO 4204 Relay Module – Installation Instructions - SafeHomeCentral
    to the inside of the 4204’s cover (if the cover is used) or to the inside of the control’s cover CONNECTIONS AND SETTINGS Select and set an address for the 4204, using its DIP switch as shown in the DIP switch table Each 4204 must be assigned a unique address so the control can identify and communicate with the 4204 The address
  • Control 4204 relays connected to garage doors - HomeSeer Message Board
    To activate the relay, you need to send a sequence of keys like this: [User Code] + # + 7 + 01 The user code is the code you use to arm disarm The number 7 tells the panel to close the relay and the 01 is the relay number on the 4204 module To reset the relay, I use the sequence [User Code] + # + 8 + 01 Hope that helps Andy
  • Honeywell ADEMCO 4204 Installation Instructions - ManualsLib
    Page 1 1 “OFF” and when the GENERAL INFORMATION installation is completed, the unit’s tamper-protected The ADEMCO 4204 Relay Module provides from one to cover must be replaced four dry, form-C (SPDT) relay outputs to compatible control communicators Page 2 Cet appareil ne doit pas causer d’interférences nuisibles (2) Cet appareil
  • INSTALLATION AND SETUP GUIDE - ServiSecurity
    The ADEMCO 4204 Relay Module adds from one to four dry, form C (SPDT) relay outputs to compatible control communicators It interfaces to the control’s keypad wiring The 4204 can be mounted inside the control’s cabinet or mounted remotely If mounted remotely, the 4204 has a built-in tamper switch that allows it to detect and report the