Boiler Operating Engineer Licensing in State of Montana - Steam Forum Can operate steam boilers operated not in excess of 250 psi, water boilers operating not in excess of 375 psi and 450°F temperature, and steam-driven machinery not to exceed 100 horsepower per unit except traction and hoisting engines Third Class Boiler Engineer:
Stationary Operating Engineer Licensing in New Jersey - Steam Forum High pressure boilers must be manned within sight and sound of boilers at all times when in operation Seals of 1st Class, 2nd Class and 3rd Class Engineers Licenses are required throughout the state The State of New Jersey has 13 stationary engineer's licensing levels But, it is important to understad some common phrases and licensing
New Zealand Certificate in Energy and Chemical Plant (Process Operation . . . Forced once through circulation boilers up to 3MW Finally, no limit on size or pressure for water-tube steam boilers and hot water boilers with a steam or gas head for pressurisation A Level 2 has the skills and knowledge required by people who are responsible for the operation of a boiler of limited attended, fully attended, or unattended type
California Operating Engineers License - Steam Forum A valid Boiler Operator License or Steam Engineer License is required by the City of Los Angeles for a person to operate, within city limits, one or more high pressure steam boilers rated above 5 horsepower (high pressure steam is steam in excess of 15 PSI {PSI - pounds per square inch}) - L A M C Sec 97 0201
Stationary Operating Engineer Licensing in Oklahoma, Tulsa and Oklahoma . . . In addition to those boilers operable with a Third and Fourth Class Boiler Operator License, any person holding a Second Class Boiler Operator License is qualified to operate and maintain all boilers with energy inputs exceeding 12,500,000 btu hr or its equivalent Qualifications:
Stationary Operating Engineer Licensing in Louisiana, New Orleans A Special Operator license to operate boilers, steam or internal combustion engines specified in this code, shall be an operating engineer, having at least 2 years practical experience as an apprentice in the operation of steam engines, boilers, or internal combustion engines Applicants for a Special Operator licenses coming under the
Stationary Operating Engineer Licensing in Nebraska, Lincoln, Omaha This examination shall cover hot water boilers and equipment, steam generators and their auxiliary equipment, and their construction, operation, maintenance and defects; the use, operation and care of electrical motors; and the causes and prevention of smoke Qualifications for a City of Omaha Stationary Engineer are as follows:
Stationary Engineer Licensing in District of Columbia DC - Steam Forum Class 6 – Steam and Hot Water Heating Boiler Engineer; (a) The experience and knowledge to take charge of and operate steam and hot water heating boilers, where the steam pressure does not exceed fifteen pounds per square inch (15 psi) and the steam or hot water heating boilers do not exceed two hundred (200) horsepower (twenty eight thousand
Rhode Island Operating Engineers License - Steam Forum A stationary engineer shall be in charge of all boilers, stationary engines, prime movers, diesel engines, gas engines, and steam turbines over 100 HP A stationary engineer, boiler operator, or refrigeration machine operator shall be on duty at all times and shall be in the vicinity of the mechanical equipment room and shall not leave the
Connecticut Operating Engineers License - Steam Forum Bridgeport Blue Seal Unlimited on Boilers; Bridgeport Boiler Tender; Bridgeport Red Seal Limited on Boilers; New Haven New HavenCity Hall 200 Orange Street New Haven, CT 06517 Local residency is not required to apply for license Licenses from other jurisdictions is recognized for a reciprocal and experience The City of New Haven has 3