- electrical - Confusion over 220 and 230 volt outlets - Home Improvement . . .
220 wasn't even the original voltage It was 200, or to be more precise 100 100 split phase, and 500V for streetcars It was also DC A bump was made to 105V etc in coordination with light bulb makers Then another bump to 110 220 550, and then, power companies yielded to the inevitable and switched to AC
- electrical - How many amps per leg on a 220V circuit? - Home . . .
220-240v in the U S is 2 legs of a single phase The 2 legs come off the transformer and have a center tap (the neutral) each leg to neutral is 120v or 240 leg to leg If it were part of a multi phase phase system the leg to leg value would not be the same as adding each leg to neutral voltage –
- electrical - Wiring for 1 phase 220 volt bandsaw - Home Improvement . . .
Splitting DC supplies like that with "taps" is a recurring theme in Edison and GE designs of that age Edison's goal was to reduce voltage drop - 220V distribution has 1 4 the losses of 110V But DC switches need elaborate arc suppression so 110 was better for lighting than 220 220 was better for motors
- electrical - Old kitchen range only has 3-wires, how to wire correctly . . .
Stack Exchange Network Stack Exchange network consists of 183 Q A communities including Stack Overflow, the largest, most trusted online community for developers to learn, share their knowledge, and build their careers
- GFCI Required for 220v outlets? - Home Improvement Stack Exchange
It is a 2020 NEC change 210 8(A) Dwelling Units All 125-volt through 250-volt receptacles installed in the locations specified in 210 8(A)(1) through (A)(11) and supplied by single-phase branch circuits rated 150 volts or less to ground shall have ground-fault circuit-interrupter protection for personnel
- receptacle - What types of electrical outlets are found in a typical . . .
Note, also, that you can perfectly well plug a 15 amp plug into a 20 amp outlet I have exactly that situation 3' from me--I had an electrician run an extra line, it feeds two pairs of 20 amp outlets (the cost of two pairs of 20 amp outlets vs a single pair of 15 amp outlets was only a few dollars )
- How to connect a 220v gfci that has no neutral coming from the load
On a boat dock with a220v boat lift I have pulled 2 hots and a ground as that’s all that is required to operate the lift motor My Bldg dept is requiring a GFCI 220 breaker I assume the pigtail wi
- electrical - How can I determine circuit breaker requirements for an . . .
220 55 Electric Ranges and Other Cooking Appliances — Dwelling Unit(s) The load for household electric ranges, wall-mounted ovens, counter-mounted cooking units, and other household cooking appliances individually rated in excess of 1 3 4 kW shall be permitted to be calculated in accordance with Table 220 55
|
|
|