- What are the Matrix-UPS operating temperature limitations? - APC
The Matrix-UPS will operate within all standard specification ratings in a surrounding (or environmental) temperature range of 0°C to +40°C (+32°F to +104°F) The internal temperature limitation for the Matrix-UPS as reported through PowerChute plus software may be as high as +70°C (+158°F)
- Symmetra LX - Internal battery temperature threshold violation
When you say the internal self-test passed, when did does that occur? Typically for swollen batteries in an LX, disengaging the module either by pulling it out of the frame a few inches or turning the black knob on the front to the "off" position and allowing them to cool (maybe point a fan at them, too) will cause the swelling to go down
- APC Symmetra PX 20kW Scalable to 40kW N+1 - SY20K40F
Symmetra PX SY20K40F is a high-efficiency 3-phase UPS that is scaleable as your data center grows up to 40KW 40KVA Suitable for small to medium data center application Includes two power modules ( SYPM10KF), two battery modules (SYBT4) and one SNMP Card (AP9617 or newer)
- Symmetra PX 10–40 kW and 20 kW 208 V Operation manual
Symmetra PX 10–40 kW and 20 kW 208 V Operation manual Date: Dec 13 2016 | Type: User guide Languages: English | Version: V2 Document Number: SPD_MPOD-9JXD4F_EN Files File Name: MPOD-9JXD4F_R2_EN pdf Related products Product Ranges: Configurable Power Distribution
- Solved: Internal temperature is 50C? - Schneider Electric Community
50ºC is a touch high but not concerning if the UPS is running on battery with a load I would just make sure you do your best to make sure the UPS is well ventilated and the ambient temperature around it is somewhere around 20-25ºC ideally This will also help the longevity of the battery itself
- APC Symmetra RM Operation Manual - Schneider Electric
It may be operating in any one of the following modes: On-Line, On-Battery, Command-Bypass, or Maintenance A mains power failure has occurred, and the battery modules are supplying power to the load equipment Power to the load is being supplied directly by the mains power source The UPS is removed from the circuit
- Symmetra PX family of products; Operation manuals - APC USA
Operation manuals for Symmetra PX 3 phase products Product line: Symmetra PX 3 Phase UPS Products Environment: All Modules All serial numbers Cause: Operation manuals for Symmetra PX products Resolution: Please refer to attached PDF files Released for: APC USA
- Symmetra 40K (SYCF40KF) - Internal Temperature 100F
Our Symmetra 40K has an Internal Temp alert of a little over 100F I checked all the batteries and they seem ok Is it possible this is coming from a different place in the unit?
|
|
|