  • SHEET 4 - ABSORPTION TRENCH Model (1) - Byron Shire
    Effective size range from 0 25 - 0 75 mm, typical value 0 35 mm 5 100 mm diameter sewer-grade PVC pipe (pre-perforated) See Sheet 5 for alternative design for low-pressure dosing
  • Domestic Stormwater Drainage Systems | City of Wollongong
    For each additional 25 m² of roof area or part thereof, 1 m³ of additional absorption trench must be provided Location and siting Absorption disposal systems must be sited across the gradient of the site and may be used in series i e 2 x 3 m³ if space becomes a problem (see diagram below)
  • Application - City of Parramatta
    Infiltration absorption trenches and infiltration basins are the two types of infiltration systems that can be used as a method of stormwater disposal for eligible residential dwellings
  • HYDRAULIC CALCULATIONS
    ABSORPTION TRENCH DESIGN Total area draining to absorption = 327 4 m² Impervious area draining to absorption = 173 5 m² Percentage impervious area draining to absorption = 53 0 % 10 year ARI 60 minute rainfall intensity = 57 4 mm hr Design ARI considered 5, 10, 20, 50, 100 = 100 years 10 year ARI runoff coefficient = 0 727
  • STORMWATER DRAINAGE FOR UNSERVICED ALLOTMENTS
    The length of absorption lines in metres is to be one tenth of the roof area (in square metres) with a minimum length of 9 metres 4 1 At commencement of the absorption lines, provide a distribution pit 450 x 450 x 450mm 4 2 Absorption trenches to be a minimum of 450mm wide, not more than 400mm deep and a minimum of 3 metres apart 4 3
  • Infiltration Trench Fact Sheet - clearwatervic. com. au
    Table 1 below will help you determine how big you infiltration trench needs to be Your infiltration trench should be 800mm deep, and 450mm wide, as shown in Figure 2 below To comply with the DTS table you must have 200mm of soil cover over your trench Soil cover less or greater than 200mm will not perform as well and not meet the standard
  • Microsoft Word - Fact Sheet - Absorption Trench Specifications
    An absorption trench must measure 500mm wide, 900mm deep and 40m long and all works must be completed by a licensed plumber Any questions regarding absorption trenches can be directed to Council’s Building Surveyors on (02) 6728 8200
  • Required Information for the installation of Trenches - Hornsby Shire
    Position of all roof, surface and subsoil drainage pipelines to their points of discharge Calculations for the required length of absorption trenches are to be made in accordance with the Australian Standard AS1547:2012 The following table contains a guide for trench length for wastewater disposal by sub-soil absorption