- Deflection Limits - Structural engineering general discussion - Eng-Tips
Ignoring vibrations as a servicability check, a 35-foot long beam would have a maximum live load deflection, using this criteria, of 1 17 inches The maximum dead + half live load is 1 5 inches If then we take T Galambos's paper from 1986 (published in ASCE Journal of Structural Engineering) the probability of seeing the actual deflection is
- Deflection check - Structural engineering general discussion - Eng-Tips
Calculate the deflection of the supporting beams B1A and B1B (at he location where they support B2, whichever one you're looking at they'll all be different obviously) And then by geometry you can determine how much influence the deflection of B1A and B1B have on the globabl deflection of B2
- Deflection - Structural engineering general discussion | Eng-Tips
By now a RC building is allowed to sustain a 1 250 total actual deflection under the applied total service level load with a proper calculation of the deflection, including stiffness degradation by mechanical cracking and creep (obviously checked generally in approximate ways) AS LONG what is called the active deflection doesn't surpass 1 cm or
- Deflection Criterias for Folding Partition - Eng-Tips
Does this deflection criteria only apply for the partition load (20psf) For the example I have, I have provided a W16 beam which also supports wood roof trusses The dead load from the roof trusses causes the steel beam deflect 1" This 1" deflection will be present when the track for the folding partition is installed
- deflection limits - Student Engineer General Discussion - Eng-Tips
From International Building Code (IBC) Table 1604 3 Deflection Limits: Note i) reads " l = Length of the member between supports For cantilever members, l shall be taken as twice the length of the cantilever " Therefore for each "position condition" in the table, the allowable deflection is some fraction of length of the given member
- Brick Cladding Deflection Limits 3 - Eng-Tips
thanks DaveAtkins Unfortunately by our code I have to meet L 720 deflection limits I agree that the brick veneer would follow the same curvature as the studs behind them, but the L 720 deflection limits are based on the brick veneer extending the full height of the stud wall, with the maximum deflection at the wall mid-height
- brick deflection - Structural engineering general discussion - Eng-Tips
From what I understand, brick deflection limit of L 600 comes from BIA Tech Note 17B for lintel beam If you are talking about vertical drift of frame, which implies theoretical zero at base and drift X at top, then Height 300 should be applicable due to the cantilever nature
- Brick Deflection Limits 1 - Eng-Tips
Australian code has not total deflection limit but limits deflection to L 500 for articulated brickwork (joints ar 18' or less) and L 1000 if not jointed 3" at L 600 is equivalent to about 15' so similar to the aticulated brickwork span in the Australian code This agrees with haynewp's comment suggesting jointing the brickwork
|
|
|