  • Understanding the 75°C vs 90°C column in Ampacity Table. . .
    The columns indicate how much amperage is required to raise the temperature of that size conductor to that column's temperature under standardized conditions So a 2 0 XHHW will reach 75°C at 135A and 90°C at 150A The wire insulation is good for 90°C, so for sizing the wire, we can use the
  • Table 300. 5 interpretation - Electrician Talk
    For a given column of Table 300 5 ("minimum cover requirements") there is a potential overlap of the various rows The one that concerns me at present is Column 2 (IMC and RMC conduit) If it's buried in a trench below 2" of concrete or equivalent, but also goes under a parking area in a
  • NEC says MC EMT can be unstrapped when run through. . .
    Can I get some verification that I'm interpreting NEC correctly here? I'm not asking what's the best practice I'm asking on the proper interpretation of the code I've gotten in numerous discussions with journeymen ( foremen) on whether MC Romex EMT can run unsupported over trusses in the
  • Gas station wiring requirements - Electrician Talk
    NEC 2017 514 8 Underground Wiring ENHANCED CONTENT Fuel spilled in the vicinity of gasoline dispensers seeps into the ground and could migrate into underground electrical conduits Therefore, all conduits installed below the hazardous locations of a motor fuel dispensing facility are required to be sealed within 10 feet of the point of emergence from below grade This boundary seal minimizes
  • Receptacle above drop ceiling? - Electrician Talk
    Is there anything in the NEC prevenenting a receptacle from being installed above a drop ceiling? Either in a plenum or non-plenum ceiling? Can't seem to find an article I know Cords or SO cords cannot be ran in a drop ceiling
  • Branch Circuits - Electrician Talk
    Branch circuits The distinction between a branch circuit and a feeder can be a source of confusion for the Code user The first step in eliminating this confusion is to understand that the NEC defines a branch circuit as “the conductors between the branch-circuit final overcurrent device protecting the circuit and the outlets” (such as receptacles or lights) [Article 100]
  • PowerPoint Presentation
    The NEC does not define ranges, ovens or cooktops but based on manufacturers usage a range is a unit that has a cooktop and oven built together in one appliance An oven is just a single or double appliance for baking , roasting, etc A cooktop is just the burners without the oven
  • NEC and running multiple 3 Phase feeders in single conduit
    Does NEC allow running multiple 480V 3 Phase Power load conductors in a single conduit instead of running each 3 phase loads conductors in separate conduits?