  • Top or Bottom of Footing? | Eng-Tips
    Frost depth always has been and should be to the bottom of the footing You are trying to avoid a condition where frost occurs in the soil directly under a footing and in which case the soil expands (or rather the moisture freezes and expands within the soil matrix) and dislocates the footing
  • Sources for Frost Depth Values | Eng-Tips
    Hello all, this is my first post here so please bear with me Where do you go to find accurate frost depth line values? At my job, we often have to design footers foundations rapidly so as to get them to a costumer for the purposes of an estimate Because everything needs done ASAP, contacting
  • Drilled Pier Frost Heave | Eng-Tips
    Hello, I am currently designing concrete drilled piers, and per the geotech report, the recommendations incur a 1600 psf design stress for potential frost heave The recommendations also state that placing friction reducing material can be considered as an alternate option to prevent damage
  • Frost Depth - Eng-Tips
    Frost depth also tends to presume a bit of "heated building" in the tabulated numbers, so keep that in mind for say, a freezer building, unheated storage, etc
  • Frost Protection for Interior Footings | Eng-Tips
    I'm looking at a set of structural plans and trying to understand why the exterior footings need to be placed below the frost line, but the interior footings are able to be placed right below the slab on grade with no foundation pier Is there a construction step that's done to ensure that heave is not an issue for interior footings slab on grade vs exterior footings? I know the soil below
  • When to Go Down to the Frost Depth | Eng-Tips
    I always hear that the footings have to be placed below the frost depth but does that apply to any footing? For a job where the local code indicates frost depth of 42”, all exterior bldg footings are placed at that depth but when it comes to the exterior stairs, they only go down 18” only!! The
  • Which soils are most susceptible to frost heaving? | Eng-Tips
    However there is still some potential for frost heave, especially of there are variations in the soil As mentioned in the other thread, would be best to insulate footings having inadequate cover (side of wall below grade and laterally over footing) to maintain soils thawed under footing
  • Exterior Large Equipment Pad with deep frost depths | Eng-Tips
    Frost heave isn't really caused by just the moisture in the soil freezing (and the subsequent small volume increase) It becomes an issue when ice lensing happens This is when a horizontal layer of ice forms and continues to grow in thickness as water is drawn into the freezing layer through capillary action in the soil If you have non-frost susceptible soil (large granular fill), capillary