The garage and or carport shall be separated as required by Table R302 6 Openings in garage walls shall comply with Section R302 5 Attachment of gypsum board shall comply with Table R702 3 5 The wall separation provisions of TableR302 6 shall not apply to garage walls that are perpendicular to the adjacent dwelling unit wall
- Step from garage into House?? - The Building Code Forum
--1994, Section 411 2 8: "Connection of an automobile parking garage with any room in which there is afuel-fired appliance shall be by means of a door way with a raised sill at least 8 inches above the garage floor or through a vestibule providing two door separation " So the southern code was concerned with ignition of gasses
- Equipment Bollard in a Residential Garage - The Building Code Forum
Re: Equipment Bollard in a Residential Garage I could be mistaken but I believe NFPA 54 addresses it as sufficient clearance shall be maintained to permit cleaning, service etc with no dimensional criteria Edit: Strike cleaning service was winging without an available racket and forgot garage in OP Thanks Haz Mueller
- Minimum Floor Slope for Drainage | The Building Code Forum
The building code requires that a garage floor be sloped towards the door, but does not specify a minimum slope It is usually 1 8” to 1 4” per foot Here is the citation from the International Residential Code (IRC):
- Private Garages - The Building Code Forum
Is a private garage also a parking garage I can see this answer going both ways, with out the aid of definitions Or is a parking garage the same as an open garage only with walls If so, then a parking garage and private garage are the same I have tried to treat them as 3 distinct types of buildings, private garage, parking garage, open garage
- Elevation of ignition source | The Building Code Forum
Commercial building with underground parking, with the boiler room separated from the garage by a single door The design of the boilers is such that all sources of ignition are at least 18" above the floor The circulation pumps (12 of them) are all on housekeeping pads, but the motors, etc
- Garage Floor Drain - The Building Code Forum
Needing some info on garage floor drain Have read codes that garage floor must slope out or to a drain Have new residential construction with attached garage The builder installed what he identifies as floor drain I drained the livewell from my boat in garage floor Floor is completely flat without any slope to drain or towards door
- Commercial Repair Garages - The Building Code Forum
One exit door of minimum width of 32", in a nonsprinklered bldg would provide egress for 160 person For the square footage provided that's 22 9375 sq ft per person Since the hazard is the vehicle with the gasoline or other fuel, I personally would use the parking garage (200 sq ft person gross) number if there were any questions
|
|
|