- NC Garage Legal Finish Requirement | The Building Code Forum
The garage is 100% residential- not a business The first floor has lights outlets, the second floor only has a preexisting light fixture (exterior light) from the original house and no added wiring
- Step from garage into House?? - The Building Code Forum
I do not see anywhere in the IRC 2015 that requires a step from the garage into the house I saw the opening penetrations R302 5 Garage section R309 Is the step still a requirement and if so is there a minimum dimension?
- HVAC in a garage - The Building Code Forum
Codes do not permit duct openings in a residential attached garage, for obvious reasons I ran across one yesterday where it appears that the contractor is placing an air handler in a garage under living space My first reaction is -not permitted- however as I thought about it I figured the
- Garage distance separation from dwelling - Section R309
Re: Garage distance separation from dwelling - Section R309 Uncle Bob, That's how I see it (I just don't believe it) I would not interpret measuring from overhang Any other comments on that? I'll probably stay 5' back The area where the two structure meet is only about 30" of wall length, but there is a window in the garage in that 30"
- Group U private garage building - The Building Code Forum
Each private garage shall be not greater than 1,000 square feet (93 m2) in area Multiple private garages are permitted in a building where each private garage is separated from the other private garages by 1-hour fire barriers in accordance with Section 707, or 1-hour horizontal assemblies in accordance with Section 711, or both
- S-1 S-2 Regarding Parking Garage - The Building Code Forum
Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage" Section 311 3 Classifies "Parking garages, open or enclosed" as a group S-2 Occupancy Because the Business Occupancy is a hazard to the S-2 occupancy, a fire barrier wall must be constructed between the two
- fire separation in garages - The Building Code Forum
When constructing split entry's, we alway's framed around the steel I-beam and post in the garage, installed gyp and taped the seams Same on the fur-down (duct covering)and ceiling gyp, just tape unless spray texure was being installed, alway's thought that was the code are we requiring something different now?
- Path of egress not thru garage needed for non-living space above . . .
The city is telling us that we have to have a means of egress from the space that does not require travel through the garage, per IRC Section R311 1 To do this, they want us to build a wall across the back portion of our garage to create an enclosed hallway from a man door out the back of our garage to the stairs that lead up to the space
|
|
|