英文字典中文字典Word104.com



中文字典辭典   英文字典 a   b   c   d   e   f   g   h   i   j   k   l   m   n   o   p   q   r   s   t   u   v   w   x   y   z   


安裝中文字典英文字典辭典工具!

安裝中文字典英文字典辭典工具!








  • NC Garage Legal Finish Requirement | The Building Code Forum
    The garage and or carport shall be separated as required by Table R302 6 Openings in garage walls shall comply with Section R302 5 Attachment of gypsum board shall comply with Table R702 3 5 The wall separation provisions of TableR302 6 shall not apply to garage walls that are perpendicular to the adjacent dwelling unit wall
  • Equipment Bollard in a Residential Garage - The Building Code Forum
    Re: Equipment Bollard in a Residential Garage I could be mistaken but I believe NFPA 54 addresses it as sufficient clearance shall be maintained to permit cleaning, service etc with no dimensional criteria Edit: Strike cleaning service was winging without an available racket and forgot garage in OP Thanks Haz Mueller
  • Minimum Floor Slope for Drainage | The Building Code Forum
    The building code requires that a garage floor be sloped towards the door, but does not specify a minimum slope It is usually 1 8” to 1 4” per foot Here is the citation from the International Residential Code (IRC):
  • Pex pvc pipes in a garage - The Building Code Forum
    Openings from a private garage directly into a room used for sleeping purposes shall not be permitted Other openings between the garage and residence shall be equipped with solid wood doors not less than 13 8 inches (35 mm) in thickness, solid or honeycomb-core steel doors not less than 13 8 inches (35 mm) thick, or 20-minute fire-rated doors
  • Private Garages - The Building Code Forum
    Is a private garage also a parking garage I can see this answer going both ways, with out the aid of definitions Or is a parking garage the same as an open garage only with walls If so, then a parking garage and private garage are the same I have tried to treat them as 3 distinct types of buildings, private garage, parking garage, open garage
  • Commercial Repair Garages - The Building Code Forum
    One exit door of minimum width of 32", in a nonsprinklered bldg would provide egress for 160 person For the square footage provided that's 22 9375 sq ft per person Since the hazard is the vehicle with the gasoline or other fuel, I personally would use the parking garage (200 sq ft person gross) number if there were any questions
  • Garage Floor Drain - The Building Code Forum
    Needing some info on garage floor drain Have read codes that garage floor must slope out or to a drain Have new residential construction with attached garage The builder installed what he identifies as floor drain I drained the livewell from my boat in garage floor Floor is completely flat without any slope to drain or towards door
  • Elevation of ignition source | The Building Code Forum
    Commercial building with underground parking, with the boiler room separated from the garage by a single door The design of the boilers is such that all sources of ignition are at least 18" above the floor The circulation pumps (12 of them) are all on housekeeping pads, but the motors, etc