  • NC Garage Legal Finish Requirement | The Building Code Forum
    The garage and or carport shall be separated as required by Table R302 6 Openings in garage walls shall comply with Section R302 5 Attachment of gypsum board shall comply with Table R702 3 5 The wall separation provisions of TableR302 6 shall not apply to garage walls that are perpendicular to the adjacent dwelling unit wall
  • HVAC in a garage - The Building Code Forum
    The leakage around a garage door and the cubic volume of a double car garage should provide an adquate supply of combustion air to any "B" vented unit We have encouraged CO detectors in homes with attached garages for years especially if a HVAC unit is installed in the garage
  • Equipment Bollard in a Residential Garage - The Building Code Forum
    Re: Equipment Bollard in a Residential Garage I could be mistaken but I believe NFPA 54 addresses it as sufficient clearance shall be maintained to permit cleaning, service etc with no dimensional criteria Edit: Strike cleaning service was winging without an available racket and forgot garage in OP Thanks Haz Mueller
  • Minimum Floor Slope for Drainage | The Building Code Forum
    The building code requires that a garage floor be sloped towards the door, but does not specify a minimum slope It is usually 1 8” to 1 4” per foot Here is the citation from the International Residential Code (IRC):
  • 2024 Portal Frames - The Building Code Forum
    By code, one could use a portal frame to support a 20’ wide garage door, but not this case with a much smaller opening If the three windows were replaced with a triple, mulled unit, I would assume it would be acceptable, which seems somewhat ridiculous Portal frames are not just used for garage doors (except for the PFG)
  • Garage Floor Drain - The Building Code Forum
    Needing some info on garage floor drain Have read codes that garage floor must slope out or to a drain Have new residential construction with attached garage The builder installed what he identifies as floor drain I drained the livewell from my boat in garage floor Floor is completely flat without any slope to drain or towards door
  • Commercial Repair Garages - The Building Code Forum
    One exit door of minimum width of 32", in a nonsprinklered bldg would provide egress for 160 person For the square footage provided that's 22 9375 sq ft per person Since the hazard is the vehicle with the gasoline or other fuel, I personally would use the parking garage (200 sq ft person gross) number if there were any questions
  • Elevation of ignition source | The Building Code Forum
    Commercial building with underground parking, with the boiler room separated from the garage by a single door The design of the boilers is such that all sources of ignition are at least 18" above the floor The circulation pumps (12 of them) are all on housekeeping pads, but the motors, etc