  • Generac Propane Consumption - Printable Version - WoodNet
    RE: Generac Propane Consumption - frule - 07-26-2016 I have an 8 kW Generac and it used about 100 gallons in 72 hours (near you, in Walland, TN) I pushed an LP furnace, well pump, several lights, freezer, fridge, microwave, 1700W commercial Bunn coffee machine, 65" TV, computer setup, etc
  • Whole House Generator - Woodnet
    I ahve a 7 year old 22KW Generac (with a Honeywell label) that urns off a 500 gallon (dedicated) LP tank Our outages are mostly 2-4 hours, but we have had 1 that wass 22 hours, and another that went maybe 14 hours No problems with the generator yet Generac does provide about 80% of the home standby units in the US, so there's that to consider
  • Generator Mishap | Oklahoma Shooters
    Generac 10000005117 6 3A N1, N2, T1 Fuse For New Style Transfer Switches Used in MANY Generac Transfer Switches to protect the N1, N2, T1, T2 and other control circuits Can blow from power surges, wiring errors, and other issues related to the control wiring from the generator to the
  • Generac Propane Consumption - Printable Version - WoodNet
    RE: Generac Propane Consumption - jteneyck - 07-26-2016 A bit of a tangent, but when I had a Generac installed I found that the cost between a 10 KW unit with a transfer switch that could handle X number of circuits wasn't really all that much cheaper than the 17 KW unit with whole house transfer switch I decided on A couple of thousand $'s
  • Generator Questions
    The Generac model that I was looking at probably falls into the category The Westinghouse model (thanks Mr Don_M) seems better for fuel consumption I don't want to install and plumb a 500 gallon propane tank just to run a whole house generator, but I'm not averse to a couple of 20 lb portable tanks
  • Generac Propane Consumption
    A bit of a tangent, but when I had a Generac installed I found that the cost between a 10 KW unit with a transfer switch that could handle X number of circuits wasn't really all that much cheaper than the 17 KW unit with whole house transfer switch I decided on A couple of thousand $'s
  • Whole house generator follow-up (fuel use) - Woodnet
    I'm set up much the same way as Ray is, I have the Generac (actually a Generac with a Honeywell label) 22KW generator My propane setup is a little different, I have the genny on a 500 gallon tank, and the house has a separate 330 gallon tank The house tank feeds the gas cooktop and the shop heat, and when called for, the house furnace
  • Propane gas flow to a generator regarding pipe size issues
    I have a Generac 8KW standby generator that runs on propane gas The manual says to use 3 4" pipe to the generator From my 1,000 gallon LP tank, I have 1" black iron pipe that transitions to 3 4" pipe But the last 6-7 feet of this run is only 1 2" pipe So I have a run that is 60 feet of 1', then 40 feet of 3 4", then 6 feet of 1 2" black