  • MS-5210UD Fire Alarm Control Panel with Built-in DACT and Remote-Site . . .
    3 0 Amps of Notification Appliance power, expandable to 6 0 amps (meets the critical power requirements for ADA and UL-1971 devices) Two built-in, fully programmable Form-A relays - expand-able to four with two Form-C relays required) 24-Volt operation Built-in voltmeter measures: Zone voltage Primary AC line voltage Battery voltage
  • FIRE-LITE ALARMS MS-5210UD CONTROL PANEL MANUAL | ManualsLib
    The primary power source for the MS-5210UD is 120 VAC, 60 Hz, 2 3 amps and for the MS-5210UDE is 220 240 VAC, 50 Hz, 1 2 amps Run a pair of wires (with ground conductor) from the protected premises main breaker box to TB1 of the main circuit board
  • Fire Alarm Control Panels MS-5UD MS-10UD Series - Honeywell
    devices, and a fire alarm control panel (FACP) with remote notifica-tion capability—can provide early warning of a developing fire Such a system, however, does not assure protection against property damage or loss of life resulting from a fire An emergency communication system—typically made up of an
  • MS-5210UD MS-5210UDE - The Fire Panel
    Follow the instructions in the installation, operating, and programming manuals These instructions must be followed to avoid damage to the control panel and associated equipment FACP operation and reliability depend upon proper installation
  • Fire•Lite MS-5210UD UDE Manual: AI Chat PDF | Manualzz
    This fire alarm control panel offers features such as 10 Style B initiating device circuits, two NFPA Style Y notification appliance circuits expandable to four, and a built-in digital communicator It supports programmable zone IDs, alarm verification, and interfaces with Fire•Lite annunciators
  • Fire-Lite MS-5210UD Notifier SFP-1024 Replacement Board
    Expands NAC power from 3 0 to 6 0 amps and system power from 3 6 amps to 6 6 amps — NAC-REM Notification Appliance (Signal) Circuit, Relay Expander Module Adds two (Class A) NACs and two Form-C relays — CAC-10F Class A Converter Module
  • Fire-Lite MS-5210UD Fire Alarm Control Panel . . . - Fire Alarm Resources
    Download Fire-Lite MS-5210UD Fire Alarm Control Panel with Built-in DACT and Remote-Site Upload Download Capability PDF Fire Alarm Resources has free fire a
  • FIRE-LITE ALARMS MS-5UD SERIES MANUAL Pdf Download
    The minimum system components required for compliance with the appropriate NFPA standard are listed below: MS-5UD MS-10UD Control Panel Contains the main control board, cabinet (backbox and door), main power supply and transformer