英文字典中文字典Word104.com



中文字典辭典   英文字典 a   b   c   d   e   f   g   h   i   j   k   l   m   n   o   p   q   r   s   t   u   v   w   x   y   z   


安裝中文字典英文字典辭典工具!

安裝中文字典英文字典辭典工具!








  • Pedestal Service | Information by Electrical Professionals for . . .
    Re: Pedestal Service Q1) Since pedestal has main disconnect, is exterior panel at house considered SUB which requires isolation on EGC Nuetral and pedestal considered Main ? A1) The post says that a four wire wire feeder is being intalled The grounded conductor must be isolated from the neutral at the house in this case
  • Boat Seat Wave Dampening Pedestal - Michigan Sportsman Forum
    What is everyone running for pedestal upgrades to help with the ride? Looking for any suggestions recommendations ideas I did run across this Springfield Ez-Ride Wave Dampening, but can't find much in regards to reviews or anything on it at this point Simply the $250 300 price tag sounds a bit more appetizing than $600+ seat
  • max current for RV pedestals? | Information by Electrical Professionals . . .
    Even though the pedestal may be loaded to the hilt, in a 3 hour period there is going to be some equipment cycle often enough for the load to be considered non-continuous The NEC has taken into account that "roughing-it" now often includes HVAC units and increased the load calculations on 50 amp RV spots from 9600 va to 12000 va
  • Pedestal service grounding | Information by Electrical Professionals . . .
    Re: Pedestal service grounding I have a three wire triplex (Bare is the neutral)feeding the sub-panel The sub-panel (Main lug) is grounded with a ground rod From the sub-panel they are running a 4-wire two hots one neutral and a ground to the gate
  • Help me identify a mobile home pedestal | Information by Electrical . . .
    One obvious need is a pedestal that is between the service connection on the street (which is also a pedestal with the meter and main breaker) and the panel on the actual mobile home itself This pedestal is near the mobile home's panel, and contains no breakers, but just a connection point for the underground feed from the meter to a flex that
  • RV site requirements | Information by Electrical Professionals for . . .
    Is it required to have a ground rod at each 50 30 20 RV pedestal Yes While not always enforced 250 32 requires a grounding electrode for any building or structure supplied by a feeder
  • Power Pedestals in RV Parks | Information by Electrical Professionals . . .
    I am working on a project in an RV park where the plan is to use one UL listed power pedestal to supply two trailer sites The pedestal is rated for 80 amp 120 240 V service and will only have one power head which will have 2-30A receptacles and 1 duplex 20 amp GFCI receptacle in the power head with 2-30 A circuit breakers and one 20 amp
  • RV pedestals and the Tap Rule - Mike Holts Forum
    The breakers inside the pedestal are fed from a single phase 240V, 125A panel bus The bus is fed by #1 copper tap conductors that are, in turn, fed by a set of lugs which also have double 6-350 barrels on each lug for the purpose of loop or daisy-chain feeders


















中文字典-英文字典  2005-2009

|中文姓名英譯,姓名翻譯 |简体中文英文字典