  • Which Viessmann boiler to buy? — Heating Help: The Wall
    Viessmann Vitorond 100 (probably the best oil-fired boiler “currently” available) Viessmann Vitocrossal 300 CU3A (Gas condensing boiler but floor mounted and has 5 stages of modulation with a high-mass water content of 13 gallons) They have been chosen based on several criteria - but primarily durability first and energy efficiency second
  • Viessmann B1KE f380 faults — Heating Help: The Wall
    Out of several installations of the new Viessmann models of boilers (B1ke B1he), most have worked flawlessly On occasion, several units (so far only the combi boiler's) express an F 380 fault code which is flame loss immediately after stabilization Resetting the boiler will have it running fine sometimes for weeks or months without further issue
  • Viessmann vitodens 200-w not working with newer control console
    Viessmann designed a replacement board that fit all Vitodens 200s of that generation that has a series of dip switches You have to get the dip switch setting right for the size boiler (the original board did not have dip switches) The replacement control board comes with an instruction sheet showing the dip switch settings for each boiler size
  • New Viessmann Groaning Resonation - Page 2 - Heating Help
    The Viessmann Vitodens 100 B1HE-199 boiler is installed on a wall right under our living room floor With honesty, I have not noticed the noises unless I am in the same room as the boiler Nonetheless, the noises do resonate to some pipes and they sound bad like something moved for the first time in a long time
  • Baxi vs. Viessmann — Heating Help: The Wall
    The Baxi company has been at the forefront of new energy conserving products for years There are so many energy efficient products that Baxi sells overseas that we may never see I have not been to Viessmann in Germany, however I have been to Viessmann in RI, and was impressed by their facility as well
  • Accuracy of Outdoor Reset Temp Sensor for Viessmann Vitodens B1KE-120 . . .
    I had a Viessmann Vitodens B1KE-120 Combi installed about 9 months ago and I've recently noticed that the temperature reported by the "external temperature sensor" according to the ViCare app reads about 9 degrees warmer than the actual temperature
  • Viessmann boiler short cycling — Heating Help: The Wall
    Hi, I have noticed my boiler Viessmann Vitodens 100-W(B1HC-26) makes a series of short cycling before starting to heat Boiler is controlled by Baxi uSense room thermostat connected via Opentherm Boiler is controlled by Baxi uSense room thermostat connected via Opentherm
  • Viessmann Fault F6 — Heating Help: The Wall
    Hi everyone, and Happy New Year I have a Viessmann Vitodens 100 combi boiler This morning the heat was off and fault code F6 was displayed I went to the Viessmann fault checker website and F6 is listed as a common code to all boilers, and it means "Fan not at standstill plug-in connection" Does anyone know what this means, and how to fix it?