安裝中文字典英文字典辭典工具!
安裝中文字典英文字典辭典工具!
|
- How to Troubleshoot a RAID Hard Drive Problems on a Dell Computer
The computer boots as expected on the remaining drive after that screen closes If the onboard diagnostics passed, you want to troubleshoot how the RAID sees the degraded drive Go to: Step 2 If they failed and you have the new Hard Drive, you want to go to: Rebuilding RAID 1
- VPLEX: Storage-volume is marked degraded then gets cleared . . . - Dell
According to storage volumes performance policies, when a LUN exceeds the latency threshold (200 ms by default, as explained in the Administration Guide) it gets declared degraded then when it gets back to the acceptable limit, it gets cleared again
- Virtual Disk Degraded and Predictive Failure Messages
Virtual Disk Degraded and Predictive Failure Messages Hi Experts We are getting following errors in OpenManage for RAID 10 There are 8 hard disks and one of them is creating this problem It is blinking green and amber A foreign configuration has been detected : Controller 0 (PERC H710 Mini)
- Dell PowerEdge RAID Controller 9 User’s Guide H330, H730, and H830
The Dell PowerEdge Expandable RAID Controller (PERC) 9 Series of cards consist of the H330, H730, H730P, H730P MX, and H830 cards PERC H330:The PERC H330 is a general purpose RAID solution card The card is available in Adapter (low profile and full height), Mini Monolithic, and Mini Blade form factors for internal storage and tape devices Figure 1 Features of PERC H330 adapter card PERC
- Avamar: GSAN Degraded and Server in Synchronizing State
Avamar may display a degraded GSAN status and a Synchronizing state in the mccli server show-prop command due to high metadata utilization, typically exceeding 90% This issue can arise from incorrect backups, replication to the GSAN, or other factors To resolve this, follow the steps outlined in Dell internal article 000047627, which detail how to reduce metadata capacity and eliminate the
- H710P controller state degraded, but pdisks and vdisks are OK
H710P controller state degraded, but pdisks and vdisks are OK Hi, I have several PowerEdge R720 servers with PERC H710P and H710P Mini (embedded) controllers that are having issues According to omreport, the controller is in a non-critical status and a degraded status: Controller ID : 1 Status : Non-Critical Name : PERC H710P Adapter Slot ID
- Dell Precision 3660 PCIe Training Error | DELL Technologies
However it is returning BIOS warning " PCIe - Training warning on device PCI tag-0400 VendorID-1093 DeviceID-C4C4 SVid-1093 SDid-742F Link Degraded maxwidth = x4 negWidth = x1" I can confirm that the PCIe-6351 is a x1 PCIe compliant device
- How to Resolve Hard Drive or solid state drive Issues on your Dell . . .
This article provides information about how to troubleshoot and resolve common hard drive (HDD) or solid state drive (SSD) issues on a Dell computer
|
|
|