Homeline vs QO | Information by Electrical Professionals for Electrical . . . The QO’s are physically smaller, so I reckon they could put the internals in the larger Homeline frame? Never took one apart to see if they are similar I know with the Eaton CH, they will trip quicker on a fault than the BR, and the BR is actually a Westinghouse design, so I know Eaton didn’t use the same guts
SquareD QO vs Homeline for residential | Information by Electrical . . . But QO prices compared to Homeline make QO a very tough sell QO Stuff is typically more than double the price of HL Is there anything about the build and reliability of QO that justifies this? I haven't heard of many issues(if any) with Homeline Not that I have had any issues with QO, it has worked great so far
QO vs HOM - worth the price? | Information by Electrical Professionals . . . One argument w QO, vs HOM, would be Homeline panels use a aluminum bus I seriously doubt the Eaton BR CH share the same guts, they were competitive makes for decades, Cutler-Hammer, CH, Bryant, then later Westinghouse, BR, before Eaton brought them together, QO, HOM, sharing the same innards other then only the QO, having the VisiTrip trip indicator flag, I can buy that statement
Square D QO Breaker Panel Question | Information by Electrical . . . It only fits QO single phase loadcenters made since they went with that style of main, sometime late 1980's I believe Definitely was by the 1990's Definitely was by the 1990's Early Homeline panels did not use this but eventually they switched to that style main breaker as well
QO 2-Pole AFCIs to be Discontinued | Information by Electrical . . . Greetings "Long time listener, first time caller " Schneider has set an end-of-service date of November 30, 2021 for the Square D QO215CAFI and QO220CAFI, their 2-pole 120 240V Combo AFCI breakers (link at bottom of post), which as far as I know are their only AFCI solution for multi-wire
Tandem Breakers in Square D QO Load Center Also, I think I was wrong on the KO’s; I think only older QO loadcenters have a KO for the hook, and newer models will have a notch already cut Square D used to sell a special tool for getting that KO punched out It’s kind of a pain really Sent from my iPhone using Tapatalk
QO twin breakers, two styles ? | Information by Electrical . . . More than once I have converted a single phase QO panel to a three phase panel by simply swapping guts Same cabinet and same cover were reused Can't get away that easily with over 100 amp main breaker panels though, but main lug only or 100 amp or less back feed type mains it works well if the original isn't too old that it is a different design
Square D QO Sub Panel | Information by Electrical Professionals for . . . In order to accommodate a portable generator circuit and mechanical manual interlock I'm installing a 200A main lug only QO 40 space panel next to my existing 200A main breaker 40 space panel, as I need additional breaker spaces I will be powering the sub panel from a 2-pole 100A breaker in the main panel
Square D QO vs Siemens - Mike Holts Forum Looking to get opinions on the use of Square D QO panels vs Siemens brand in commercial applications I've got several small Sq ft useage areas (individual rooms approx 500 sq ft) that are going to need general lighting and general purpose receps and 1 20A 250volt recep (6 spaces required) I'm
SQUARE-D QO 20 40 QUAD CIRCUIT BREAKER? No, the QO line has never had any real quads What you're looking for does not exist At one point you could get a quad-like kit of two QO 20-30 tandem breakers and a handle tie It provided two single pole 20A handles and two single pole 30A breakers tied together like a 2-pole breaker, but not really