Avamar: GSAN Degraded and Server in Synchronizing State Avamar may display a degraded GSAN status and a Synchronizing state in the mccli server show-prop command due to high metadata utilization, typically exceeding 90% This issue can arise from incorrect backups, replication to the GSAN, or other factors
Dell 1950 - degraded link width error | DELL Technologies degraded link width error: embedded i o bridge device 1 expected link width is x4 actual link width is x1 I've been to our data centre and brought the machine to back the office I've tried replacing the smaller PCI-E riser which didnt help, I've ordered the larger PCI-E riser to see if swapping that out helps
degraded virtual disk - Dell I ask as the controller, when it gets really far behind, will flag the Virtual Disk as degraded It does this to get the firmware addressed before it gets to the point of causing an issue Let me know what you are currently at for BIOS, iDrac, and raid controller, as well as what model server and controller is being used
MD3200 - Degraded Physical Disk Channel - Dell Degraded physical disk channel: 1 What Caused the Problem? A physical disk channel status was set to Degraded because of excessive I O errors or because a Technical Support Representative advised the storage array's administrator to manually set the physical disk channel status for diagnostic or other support reasons
Virtual Drive Degraded. Physical Drives OK. - Dell Good morning - I have a T410 with PERCS300 controller RAID 5 with 3 Drives The drives are cabled Open Manage is reporting that the virtual disk is degraded When I look at the Physical Disks it shows all 3 as online It lists one drive of the three though (Physical Disk 0:0) as being the Global hotspare
Storage Center Alert: RAID Devices are in a Degraded State RAID devices in a degraded state message are generally caused by a drive failure Review the alerts to determine if there are failed drives If you are not aware of any drive failures or maintenance on the array when the alert was generated, contact technical support for additional guidance
Controller degraded but disks are ok! - Dell Hi have a R710 Server with H700 Intergrate controller , according to omreport has the RAID-10 array in a degraded state: # omreport storage controller Controller PERC H700 Integrated (Embedded)Co
How to Troubleshoot a RAID Hard Drive Problems on a Dell Computer Disconnect the degraded Hard Drive and turn the computer on with it removed Once the computer boots, shut it down and reconnect the Hard Drive Boot the computer and go to Rebuilding RAID 1 in the next tab (Using the IRST Software in the operating system)
PowerStore Alerts: Cache State Change | Dell US Note: This alert can be triggered by a drive firmware upgrade This is considered normal and a benign alert (unless it persists more than 5 minutes after the PowerStore drive firmware upgrade completes)